BLOOD BANK 2026-09-11

Blood Collection Case: Professional Medical Specimen Transport System

5 Key Takeaways: Blood Collection Case: Professional Medical Specimen Transpo

  1. Topic: Blood Bank — industry context for B2B buyers and procurement teams
  2. Date: 2026-09-11 — current standards, certifications and market conditions
  3. Applications: protective cases for industrial tools, MRO, photography, drones, defense, medical devices, marine, audio
  4. Procurement: MOQ 500 pieces per Pantone color, 30–45 days lead time after tooling approval, CE/RoHS/REACH/ISO 9001
  5. Shipping: EXW Guangdong (pickup) or FOB Shenzhen / Ningbo (sea freight). 28–35 days to Hamburg / Rotterdam
Blood Collection Case: Professional Medical Specimen Transport System

Advanced Blood Collection Transport Solutions

Blood collection cases are essential for maintaining specimen integrity from patient to laboratory. KeXinMaterials provides a comprehensive range of blood collection cases designed to meet the demanding requirements of modern clinical diagnostics, blood banking, and clinical research applications.

Regulatory Compliance

UN3373 Category B Certification

All KeXinMaterials blood collection cases meet UN3373 Category B requirements for the transport of biological substances:

  • Drop test compliance: Verified to P650 performance standards at 9-meter drop height
  • Leak prevention: Multiple containment barriers prevent specimen leakage
  • Absorbent material: Minimum 200% of primary receptacle volume capacity
  • Proper documentation: Includes UN3373 marking, shipping documentation, and handling instructions

Temperature Control Compliance

Our cases support compliance with temperature requirements for various blood components:

Blood Component Temperature Requirement Recommended Configuration
Whole blood 2-8°C Standard gel pack system
Serum tubes 2-8°C (after clotting) Standard gel pack system
Plasma (EDTA) 2-8°C Standard gel pack system
Platelet concentrate 20-24°C (ambient) No cooling required
Whole blood (for transfusion) 2-6°C Enhanced gel pack system
Cryoprecipitate ≤-18°C Frozen gel pack system

ISTA 7D Thermal Performance

Every configuration undergoes ISTA 7D thermal performance testing:

  • 24-hour exposure simulation: Simulates overnight transit conditions
  • Temperature mapping: Validates uniform temperature distribution
  • Load verification: Tested at full, half, and quarter load configurations
  • Seasonal testing: Validated at both high (35°C) and low (-5°C) ambient temperatures

Product Line Overview

Single-Use Transport Cases

For one-time specimen transport with no return logistics:

  • Economical design: Cost-optimized for routine specimen transport
  • Pre-assembled: Ready to use with PCM pre-conditioned
  • Full documentation: UN3373 labels, shipper declaration, handling instructions included
  • Disposal compliant: recyclable materials where possible

Reusable Transport Cases

For established collection routes with return logistics:

  • Durable construction: EPP shell designed for 500+ loading cycles
  • Modular foam inserts: Replaceable foam for different tube configurations
  • Reconditioning protocol: Cleaning and PCM replacement service available
  • Total cost of ownership: Lower per-use cost for high-volume routes

Specialty Applications

For specialized blood banking and research applications:

  • Cord blood collection: Specialized configuration with temperature monitoring
  • Clinical trial specimens: Protocol-specific labeling and documentation
  • Stem cell transport: Extended temperature range configurations
  • Blood bank transfers: High-capacity configurations for inter-facility transfers

Technical Specifications

Standard Configuration Specifications

Parameter Small Medium Large Extra Large
Tube capacity (4ml) 24 60 120 180
External dimensions 200×150×100mm 300×200×150mm 400×300×200mm 500×350×250mm
Weight (empty) 0.3kg 0.6kg 1.2kg 1.8kg
Temperature hold 24 hours 24 hours 24 hours 36 hours
PCM requirement 2×400g 4×400g 6×400g 8×400g

Material Specifications

Outer shell options:

  • EPP (Expanded Polypropylene): Lightweight, durable, chemical resistant
  • PP / ABS / PP-ABS: Cost-effective, recyclable
  • ABS plastic: Maximum impact resistance

Insulation options:

  • Standard foam: 25mm EPE insulation
  • VIP insulation: 15mm vacuum insulation panel

Interior options:

  • Modular foam: Configurable for various tube sizes
  • V-rack integration: Accommodates standard V-shaped blood tube racks
  • Absorbent liner: Full-box or compartment-specific options

Quality Management

Manufacturing Standards

  • ISO 13485: Medical device quality management system
  • ISO 9001: Quality management system
  • GDP compliant: Good Distribution Practice for medicinal products
  • FDA registered: Device listing and material registration

Validation Support

  • ISTA 7D test reports: Published thermal validation data
  • Temperature mapping: Customer-specific studies available
  • Qualification packages: DQ, IQ, OQ, PQ documentation support
  • Material certificates: Certificate of Conformance for all contact materials

FAQ

Q: What is the difference between your single-use and reusable blood collection cases?

A: Single-use cases are designed for one-time transport with no expectation of return. They use cost-optimized materials and include pre-conditioned PCM. Reusable cases feature durable EPP shells designed for 500+ loading cycles, with replaceable foam inserts and VIP panels. Reusable cases have a lower per-use cost for high-volume routes with established return logistics.

Q: Can I customize the foam layout for my specific tube types?

A: Yes. Our modular foam system accommodates various tube sizes including 2ml, 4ml, 6ml, 8ml, and 10ml formats. We can also configure for specialty tubes such as PPT (platelet), PAXgene, and Tempus blood RNA tubes. Custom foam MOQ is 50 units per configuration.

Q: Do you provide temperature data loggers with the cases?

A: Temperature data loggers are available as an optional accessory. We offer single-use USB loggers (30-day recording, auto-PDF export) and reusable Bluetooth loggers with smartphone app alerts. For clinical trials, we provide 21 CFR Part 11 compliant loggers with audit trail support.

Q: What is the shelf life of your PCM gel packs?

A: Our 4°C PCM gel packs have a shelf life of 18 months from manufacture date when stored in original packaging at room temperature. We recommend FIFO (First In, First Out) inventory management for PCM stock.

Q: Are your cases approved for air transport?

A: Yes. All our blood collection cases are approved for air transport under UN3373 Category B regulations. They comply with IATA Packing Instruction 650 requirements. Our cases are validated for reduced pressure conditions encountered during air transport.

Ready to manufacture your protective case?

Get a free quote and reply within 24 hours on business days. 500-piece MOQ.

Request a Quote